Journal of Interventional Cardiology/2020/Article/Tab 2

Clinical Study

Midterm Clinical Impacts of Biodegradable Polymer Everolimus-Eluting Stents Compared with Durable Polymer Everolimus-Eluting Stents: A 3-Year Propensity-Matched Study

Table 2

Clinical outcomes at 1 year and 3 years.

No. of patients with at least one event (cumulative incidence) value
BP-EES
N = 327
DP-EES
N = 327

Until 1-year follow-up
 Target lesion failure 6 (1.9%) 14 (4.3%) 0.07
 Cardiac death 4 (1.3%) 7 (2.2%) 0.36
 Target vessel myocardial infarction 0 (0%) 5 (1.6%) 0.02
 Clinically indicated target lesion revascularization 2 (0.6%) 7 (2.2%) 0.10
 Clinically indicated target vessel revascularization 6 (1.9%) 7 (2.2%) 0.79
 Definite stent thrombosis 0 (0%) 4 (1.3%) 0.04

Until 3-years follow-up
 Target lesion failure 14 (4.5%) 21 (6.5%) 0.23
 Cardiac death 4 (1.3%) 8 (2.5%) 0.24
 Target vessel myocardial infarction 0 (0%) 6 (1.9%) 0.01
 Clinically indicated target lesion revascularization 10 (3.2%) 13 (4.1%) 0.53
 Clinically indicated target vessel revascularization 23 (7.5%) 17 (5.5%) 0.33
 Definite stent thrombosis 0 (0%) 5 (1.6%) 0.02

Landmark analysis between 1–3 year
 Target lesion failure 8 (2.6%) 7 (2.3%) 0.77
 Cardiac death 0 (0%) 1 (0.3%) 0.31
 Target vessel myocardial infarction 0 (0%) 1 (0.3%) 0.32
 Clinically indicated target lesion revascularization 8 (2.6%) 6 (1.9%) 0.56
 Clinically indicated target vessel revascularization 17 (5.6%) 10 (3.2%) 0.16
 Definite stent thrombosis 0 (0%) 1 (0.3%) 0.32

We are committed to sharing findings related to COVID-19 as quickly as possible. We will be providing unlimited waivers of publication charges for accepted research articles as well as case reports and case series related to COVID-19. Review articles are excluded from this waiver policy.Sign up here作为一个帮助fast-tra评论家ck new submissions.