λ = 545 nm) and a phototransistor. The titration flow system comprised three-way solenoid valves, which were assembled to allow that the steps comprising the solution container loading and the titration run were carried out automatically. The device for the solution volume determination was designed employing an infrared LED (λ = 930 nm) and a photodiode. When solution volume delivered from proposed device was within the range of 5 to 105 μl, a linear relationship (R = 0.999) between the delivered volumes and the generated potential difference was achieved. The usefulness of the proposed device was proved performing photometric titration of hydrochloric acid solution with a standardized sodium hydroxide solution and using phenolphthalein as an external indicator. The achieved results presented relative standard deviation of 1.5%."> 基于多换向流系统的光度滴定小溶液量全自动采样装置 - raybet雷竞app,雷竞技官网下载,雷电竞下载苹果

化学分析方法杂志

PDF
化学分析方法杂志/2007/文章

研究文章|开放获取

体积 2007 |文章的ID 046219 | https://doi.org/10.1155/2007/46219

Sivanildo S. Borges, Gláucia P. Vieira, Boaventura F. Reis 基于多换向流系统的光度滴定小溶液量全自动采样装置",化学分析方法杂志 卷。2007 文章的ID046219 6 页面 2007 https://doi.org/10.1155/2007/46219

基于多换向流系统的光度滴定小溶液量全自动采样装置

收到了 09年4月2007年
接受 07年6月2007年
发表 2007年8月26日

摘要

在这项工作中,提出了一种自动装置,将滴定溶液输送到滴定室,能够确定溶液的分配体积,具有良好的精度,不受时间和流速的影响。用一根保持在垂直位置的玻璃管作为滴定液的容器。电子设备被连接到玻璃管上,以控制其向滴定溶液的填充,以及将溶液逐步输送到滴定室。采用绿色LED设计的光度计对滴定终点进行检测( λ = 545 nm)和一个光电晶体管。滴定流动系统由三通电磁阀组成,这些阀的组装使得包括溶液容器装载和滴定运行的步骤能够自动进行。采用红外发光二极管( λ = 930 nm)和一个光电二极管。当从拟设装置输出的溶液体积在5到105范围内时 μ l时,输送体积与产生的电位差呈线性关系(R = 0.999)。用标准氢氧化钠溶液和酚酞作为外指示剂进行盐酸溶液光度滴定,证明了该装置的实用性。所得结果相对标准偏差为1.5%。

参考文献

  1. J. F. van Staden, M. G. Mashamba,和R. I. Stefan,“电位序贯注射滴定法测定软饮料中的总酸度”,Talanta,第58卷,第2期6,页1109-1114,2002。视图:出版商的网站|谷歌学者
  2. J. Marcos, A. Ríos,和M. Valcárcel,“基于可变流量模式的无分段流动系统中的自动滴定-第1部分:酸碱滴定的原理和应用,”分析Chimica学报,第261卷,第261号1-2,页489-494,1992。视图:出版商的网站|谷歌学者
  3. i.l. García, P. Vinas, N. Campillo,和m.h. Córdoba,“自动滴定的线性流动梯度”,分析Chimica学报,第308卷,第2期1-3页,67-76页,1995。视图:出版商的网站|谷歌学者
  4. P. B. Martelli, B. F. Reis, M. Korn,和J. L. F. C. Lima,“利用二元搜索的单段流动系统的自动电位滴定”,分析Chimica学报第387卷第1期2,页165-173,1999。视图:出版商的网站|谷歌学者
  5. A. P. S. Paim, C. M. N. V. Almeida, B. F. Reis, R. A. S. Lapa, E. A. G. Zagatto,和J. L. F. C. Lima,“自动电位流动滴定法测定药物配方中的抗坏血酸”,医药与生物医学分析杂志第28卷第2期6,页1221-1225,2002。视图:出版商的网站|谷歌学者
  6. R. S. Honorato, E. A. G. Zagatto, R. A. C. Lima, M. C. U. Araújo,“之前的分析作为流动滴定的一种方法。分光光度法测定合金和矿石中的铁分析Chimica学报,第416卷,第2期。2,页231-237,2000。视图:出版商的网站|谷歌学者
  7. J. Marcos, A. Ríos,和M. Valcárcel,“基于可变流量模式的无分段流动系统中的自动滴定-第2部分:络合滴定和氧化还原滴定,”分析Chimica学报,第261卷,第261号1-2,页495-503,1992。视图:出版商的网站|谷歌学者
  8. H. du Plessis和J. F. van Staden,“用序贯注射滴定法测定工艺废水流中的硫酸”,Talanta号,第52卷。1,页83-90,2000。视图:出版商的网站|谷歌学者
  9. M. Korn, L. F. B. P. Gouveia, E. de Oliveira,和B. F. Reis,“采用光度端点检测的流动滴定中的二元搜索”,分析Chimica学报号,第313卷3,页177-184,1995。视图:出版商的网站|谷歌学者
  10. a . J. C. Garcia和B. F. Reis,“用多交换流系统测定红葡萄酒中总酸度的仪器和自动光度滴定程序”,化学自动化方法与管理学报, 2006年第1期,文章编号83247,8页,2006年。视图:出版商的网站|谷歌学者
  11. F. R. P. Rocha, B. F. Reis, E. A. G. Zagatto, J. L. F. C. Lima, R. A. S. Lapa,和J. L. M. Santos,“流动分析中的多换向:概念、应用和趋势”,分析Chimica学报,第468卷,第2期。1,页119 - 131,2002。视图:出版商的网站|谷歌学者
  12. a . F. Lavorante, M. a . Feres,和B. F. Reis,“流动分析中的多换向:用于开发专注于减少试剂消耗的自动分析程序的多功能工具,”光谱信第39卷第3期6,第631-650页,2006。视图:出版商的网站|谷歌学者
  13. E. Ródenas-Torralba, F. R. P. Rocha, B. F. Reis, Á。Morales-Rubio和M. de La Guardia,“光度环境测量的多交换流系统的评估”,化学自动化方法与管理学报, 2006年第4期,文章编号20384,9页,2006年。视图:出版商的网站|谷歌学者
  14. F. R. P. Rocha和B. F. Reis, "一种低成本的自动光度滴定装置,"化学教育杂志第77期2,页258-261,2000。视图:谷歌学者

版权所有©2007 Sivanildo S. Borges等人。这是一篇发布在知识共享署名许可协议,允许在任何媒介上不受限制地使用、传播和复制,但必须正确引用原作。