(CV=20%) and the concentration giving CV of 10% were approximated to be 0.02 and 0.04, respectively. The assay was found to be linear within the tested range of 0.063–111.6 μg/L. The correlations between the second-generation Innotrac Aio!, Access, and AxSYM cTnI assays were good (r coefficients 0.947–0.966), but involved differences in the measured concentrations, and the biases were highest with cTnI at low concentrations. The second-generation Innotrac Aio! cTnI assay was found to be superior to the first-generation assay with regard to precision in the low concentration range. The stability of the cTnI level was best in the serum, lithium-heparin plasma, and lithium-heparin whole blood samples (n=10, decrease <10% in 24 hours at +20°C and at +4°C. There was no remarkable influence of hemodialysis on the cTnI release. False-positive cTnI values occurred in the presence of very high rheumatoid factor values, that is, over 3000 U/L. The 99th percentile of the apparently healthy reference group was 0.03μg/L. The results demonstrate the very good analytical performance of the second-generation Innotrac Aio! cTnI assay."> 评价Innotrac Aio !第二代我心肌肌钙蛋白检测:常规临床应用的主要特征 - raybet雷竞app,雷竞技官网下载,雷电竞下载苹果

分析方法在化学杂志》上

PDF
分析方法在化学杂志》上/2006年/文章

开放获取

体积 2006年 |文章的ID 039325年 | https://doi.org/10.1155/JAMMC/2006/39325

p . Hedberg j . Valkama e . Suvanto s Pikkujamsa k .马玉荣e . Alasaarela Puukka, 评价Innotrac Aio !第二代我心肌肌钙蛋白检测:常规临床应用的主要特征”,分析方法在化学杂志》上, 卷。2006年, 文章的ID039325年, 7 页面, 2006年 https://doi.org/10.1155/JAMMC/2006/39325

评价Innotrac Aio !第二代我心肌肌钙蛋白检测:常规临床应用的主要特征

收到了 2005年10月30日
修改后的 07年2月2006年
接受 2006年2月13日
发表 2006年5月25日

文摘

一个简单的可用性、敏感和快速测试使用全血,以方便处理和减少周转时间可以改善胸痛患者的管理。本研究的目的是评估Innotrac Aio !第二代心肌肌钙蛋白I (cTnI)测定。Innotrac Aio !第二代肌钙蛋白i化验与艾伯特的实验组中AxSYM第一代cTnI,贝克曼访问AccuTnI Innotrac Aio !第一代cTnI化验。我们研究血清样本来自15个患者积极的类风湿因子,但没有迹象表明心肌梗死(MI)。此外,样本具有不同的稳定性的影响矩阵和血液透析cTnI浓度进行了评估。Within-assay CVs是3.2% - -10.9%,between-assay cTnI精度从4.0%到17.2%不等。功能敏感度 ( 简历 = 20. % ) 和10%的浓度给简历被近似为0.02和0.04,分别。试验发现线性测试0.063 - -111.6范围内 μ g / L。第二代之间的相关性Innotrac Aio !、访问和AxSYM cTnI化验是好的( r 相关系数0.947 - -0.966),但不同的测量浓度,和偏见cTnI在低浓度最高。第二代Innotrac Aio !肌钙蛋白i化验发现优于第一代的实验组中测定精度在低浓度范围。稳定的肌钙蛋白i水平最好的血清的实验组中,lithium-heparin等离子,lithium-heparin全血样品( n = 10 ,减少 < 10 % 在24小时 + 20. ° C 而在 + 4 ° C 。没有显著的血液透析对cTnI释放的影响。假阳性肌钙蛋白i值发生在存在很高的实验组中类风湿因子值,也就是说,超过3000 U / L。看似健康的参照组的99 0.03 μ g / L 。结果显示很好的分析第二代Innotrac Aio的性能!cTnI化验。

引用

  1. 联合欧洲心脏病学会/美国心脏学院委员会“心肌梗死定义文档的共识联合欧洲心脏病学会/美国心脏学院委员会心肌梗死的重新定义,“美国心脏病学会杂志》上,36卷,不。3、959 - 969年,2000页。视图:谷歌学术搜索
  2. “ACC / AHA指南对不稳定性心绞痛患者的管理和non-ST段抬高心肌梗死:执行摘要和建议。报告的美国心脏病学院/美国心脏病协会实践指南专题小组(委员会管理的不稳定性心绞痛患者),“循环卷,102年,第1900 - 1893页,2000年。视图:谷歌学术搜索
  3. k . Petterson t . Katajamaki k . Irjala诉Leppanen k . Majamaa-Voltti和p . Laitinen”时间分辨荧光测定术(基金会)的免疫测定概念的快速定量测定生化心肌梗死标记从全血、血清和血浆,”发光,15卷,不。6,399 - 407年,2000页。视图:谷歌学术搜索
  4. t . Lovren l . Merio k Mitrunen et al .,“一步一体化干试剂和荧光免疫测定铕螯合标签和时间分辨荧光测定术,”临床化学,42卷,不。8 pt 1,第1201 - 1196页,1996年。视图:谷歌学术搜索
  5. p . Hedberg j . Kurittu和m . Puukka”评价的新Innotrac Aio ! 2 nd 代我心肌肌钙蛋白测定,”临床化学和实验室医学第41卷。。补充w - 125, p . S426, 2003。视图:谷歌学术搜索
  6. f .帕加尼、f . Stefini和m . Panteghini”Innotrac Aio !第二代我心肌肌钙蛋白检测:为临床使用不精确配置文件和其他关键特征,“临床化学,50卷,第1272 - 1271页,2004年。视图:谷歌学术搜索
  7. a . Dasgupta s Banerjee和p .达塔”,假阳性的肌钙蛋白I MEIA由于血清中类风湿因子的存在。消除这种干扰通过使用多克隆抗血清对类风湿因子,”美国临床病理学杂志》上,卷112,不。6,753 - 756年,1999页。视图:谷歌学术搜索
  8. a . Katrukha a . Bereznikova诉Filatov et al .,“心肌肌钙蛋白I:退化为可靠immunodetection暗示,“临床化学,44卷,不。12日,第2440 - 2433页,1998年。视图:谷歌学术搜索
  9. a . Katrukha a . Bereznikova诉Filatov, t . Esakova“生化测量血清心肌肌钙蛋白I的影响因素(审查),“临床化学和实验室医学,37卷,不。11 - 12,1091 - 1095年,1999页。视图:谷歌学术搜索
  10. a . Katrukha a . Bereznikova t Esakova et al .,“肌钙蛋白I是发布在急性心肌梗死患者血液中不是以自由形式,而是复杂的,”临床化学,43卷,第1385 - 1379页,1997年。视图:谷歌学术搜索
  11. m . Panteghini w·格哈特,f·s·苹果,f·蒂j . Ravkilde和a·h·吴”对心肌肌钙蛋白检测质量规范,”临床化学和实验室医学,39卷,不。2、175 - 179年,2001页。视图:谷歌学术搜索
  12. 埃里克森,m . Junikka p . Laitinen k . Majamaa-Voltti h . Alfthan和k·佩特森,“负干涉心肌肌钙蛋白我从一个经常发生免疫测定血清和血浆成分,”临床化学卷,49号7,1095 - 1104年,2003页。视图:谷歌学术搜索
  13. z扎曼,s . De Spiegeleer m . Gerits和n . Blanckaert”分析和临床两心肌肌钙蛋白的性能分析,“临床化学和实验室医学,37卷,不。9日,第897 - 889页,1999年。视图:谷歌学术搜索
  14. k . s . Quinn-Hall s w·贝特曼,a·h·吴s Wieczorek g . a .缩微胶片和k·t·杨”功能心肌肌钙蛋白检测的敏感性和对危险分层(Absract)”临床化学,46卷,不。p . A78补充6日,2000年。视图:谷歌学术搜索
  15. p . Hedberg j . Valkama和m . Puukka”分析性能的时间分辨fluorometry-based Innotrac Aio !心脏标记免疫测定。”斯堪的纳维亚的临床和实验室调查杂志》上,卷63,不。1,55 - 64、2003页。视图:谷歌学术搜索
  16. w·格哈特g . Nordin a·赫伯特et al .,“肌钙蛋白T和我化验显示肝素浓度降低血浆与血清:低于年末年初复苏阶段的心肌损伤,”临床化学,46卷,第821 - 817页,2000年。视图:谷歌学术搜索

版权©2006 p . Hedberg et al。这是一个开放的分布式下文章知识共享归属许可,它允许无限制的使用、分配和复制在任何媒介,提供最初的工作是正确引用。