荧光光谱法被广泛应用于生物医学光学的诊断和手术切除肿瘤。这项工作研究了激光诱导嵌入在混浊介质荧光夹杂物的荧光光谱。405 nm laser diode is used for exciting buried protoporphyrin- (PpIX) based inclusions in brain-like optical phantoms. Effects of scattering and absorption of the turbid medium on the recorded fluorescence signal and depth-resolved fluorescence were studied. Results show that optical properties of the surrounding turbid medium influence the intensity of the fluorescence signal. Absorption coefficient of the surrounding medium is the major contributor to the fluorescent signal. Analysis of the recorded fluorescence spectra shows that the effect of absorption coefficient is larger than the effect of scattering coefficient on the fluorescence intensity by nearly fivefold. The findings indicate that the fluorescence signal could be used as a biomarker of optical property variations through different stages of malignancy. This can enhance the detectability of malignant tissue for diagnostic and surgical purposes as well.
手术切除肿瘤肿物是治疗癌症最常用的方法[
荧光光谱法已用于使用由卟啉IX(PpIX的)中提供的光学对比度之后的前药的施用肿瘤的手术,在肿瘤细胞中内源合成得到高度发展的
尽管如此,许多以前的研究都集中在浅表肿瘤开发的光学方法,以便肿瘤切除过程中显示正常和癌变组织之间的边界[
据我们所知,周围的光学性质对从皮下肿瘤检测到的荧光的影响还没有被彻底研究;因此,光系数的独立效应不需要单独量化。
目前工作的目的是实验研究深度分辨荧光光谱在组织模拟光学幻影包含嵌入ppix的荧光包裹体位于表面下的不同深度。讨论了吸收系数和散射系数对荧光信号的影响。
表示用于荧光测量的光学仪器的模式图在图中描绘了
用于记录荧光光谱的光学装置的概述从脑组织样光学幻象埋入荧光夹杂物发出。
光源为405nm光纤耦合二极管激光器(0405nm 13A,集成光学公司)。(立陶宛),激光功率在CW模式下以20mw的功率交付给样品。用于收集发射的荧光信号,直径为400的收集纤维(Ocean Optics Inc.)
光学体模模仿生物组织的光学特性的两组主要为了量化在荧光强度的光学特性的影响进行了研究。光学特性被定义为覆盖健康和癌性的脑组织的相应值。对于周围介质的吸收系数的效果,四套幻影被建立了。The values of absorption coefficient ranged between 0.5 and 2 mm−1。对于每个吸收系数值,制作了5个光学幽灵的子集,对应于PpIX包裹体的5个深度,即1、3、5、7和10 mm。同样的,为了量化周围介质的散射效应,另外构建了四组光学幻影。散射系数取值范围为10 ~ 50mm−1。对于每一个散射系数值,制作了5个光学幻影的子集,对应于PpIX包含的5个深度,即1、3、5、7和10 mm。
所有的PpIX包含的荧光测量结果在黑暗的实验室环境中进行。As a preliminary measurement, five scattering coefficient values ranged from 1 to 100 mm−1构建并排列在微波腔中,然后测量包体的荧光光谱。数字
对散射系数的不同值的荧光光谱的录音。
荧光信号的强度与光学幻影的散射功率成正比。从图中可以看出
(a)用于PpIX的夹杂物的不同深度的荧光光谱的录音。(b)Fluorescence intensity at 635 nm for different depths of the PpIX inclusion in the optical phantom. Fitted curve shows exponential behaviour of the fluorescence intensity as a function of the depth.
All PpIX fluorescence spectra showed distinctive peaks at 635 and 704 nm, and thus, fluorescence intensity values at these specific wavelengths were used in further analysis of the measured spectra. Mean values and standard deviation of fluorescence intensities are plotted for different depths and for a range of absorption coefficients (from 0.5 to 2 mm−1从图表中可以看出
(a - e) 635nm处荧光强度的平均值和标准差,作为不同深度吸收系数的函数。
此外,绘制了不同深度和不同散射系数范围(从10到50 mm)荧光强度的平均值和标准偏差−1)如图表所示
(a - e) 635nm处荧光强度的平均值和标准差,作为不同深度下散射系数的函数。
值得注意的是,所有的曲线都用图形表示
在Markwardt等人的一项研究中[
此外,量化光学性质的变化对记录的荧光信号的影响是非常重要的。为了实现这一点,我们分别分析了散射和吸收的变化效应。首先,对于吸收系数,计算每个深度在635 nm处的荧光强度在上述吸收系数范围内的衰减量,计算公式如下:
(a)在635 nm处,由于不同深度的散射和吸收,荧光强度的变化。(b)散射和吸收在所有深度上的平均变化百分率。
其次,对于散射系数,计算每个深度在上述散射系数范围635 nm处的荧光强度高程,计算公式如下
通过取所有对应深度的平均值,可以对变化量进行总体量化,如图所示
可以清楚地注意到,对于吸收和散射两者的变化是可比较的(44%吸收与散射为55%)。但是,对于散射和吸收系数的相应范围是不同的。因此,我们可以说,所测得的荧光的介质的吸收系数的效果具有远高于散射系数的效果大。换言之,用于嵌入式夹杂物荧光光谱是在吸收系数的变化更敏感。
考虑到散射介质和吸收介质的荧光强度变化均呈非线性趋势,将测量的荧光量取对数,即记录的荧光量,可以将荧光强度与光学性质的关系转化为线性关系。由此我们推导出,荧光强度的对数与吸收系数的变化成反比,同样,荧光强度的对数与散射系数的变化成正比。因此,根据本研究中使用的光学特性范围,增加1毫米−1在吸收系数导致荧光强度下降18%。相比之下,散射系数增加1mm−1相当于4%,以增加荧光信号。也就是说,吸收系数的效果比通过将近五倍散射对荧光强度系数的效果大。
Stepp等人[
还推导了估算荧光夹杂物深度的分析方法[
未来工作的另一个领域可以考虑其他正在使用的激发波长[
一个可能的限制,提出的工作是注意偏差的荧光信号在吸收和散射测量。这可以解释为不可避免的错误,在定位光纤探针在光学幻影。然而,这一挫折对整体结果的影响可以忽略不计。
本文试图从实验上评价介质的光学性质对ppix填充包裹体发射的深度分辨测量荧光的影响。结果表明,吸收系数对荧光强度的影响远大于散射系数。因此,嵌入的荧光包体对周围介质的吸收系数的变化更加敏感。这对嵌入肿瘤的生物医学光学测量有深远的影响,如含有一定浓度的PpIX并被不同光学性质的生物组织包围的脑瘤。这项研究还可以扩展到研究与不同生物组织相关的其他光学特性,这反过来将提高生物医学光学诊断的准确性。
支持本研究结果的数据可从通讯作者处获得。
作者声明,本论文的发表不存在任何利益冲突。
这项工作是由大马士革大学资助的。